Everything You Should Know About IP Ratings in Switchgear Cabinets
- dsjenergyl
- Jul 7
- 4 min read

If you're planning to buy a switchgear enclosure, one term you're bound to encounter is the IP rating. Whether you're an electrical engineer, a project manager, or a switchgear cabinet supplier, understanding IP ratings is crucial. These two letters followed by numbers may seem technical at first, but they carry important information about how well your cabinet is protected from dust, moisture, and other external factors.
In this guide, we'll break down everything you need to know about IP ratings in switchgear cabinets — in plain English. By the end, you'll be confident in choosing the right enclosure for your application.
What Does IP Rating Mean?
IP stands for Ingress Protection. It's an international standard (IEC 60529) that defines the level of protection a device offers against solid particles and liquids. You'll typically see something like IP54, IP65, or IP66 listed in the specs of a switchgear cabinet.
Here's what the digits mean:
The first digit refers to solid object protection (like dust or fingers).
The second digit indicates liquid ingress protection (like water or moisture).
Let's dive deeper into what each digit means.
IP Rating Chart Explained
First Digit – Protection Against Solid Objects (0–6)
Digit Protection Level Description
0 None No protection against contact or objects
1 Very low Protected against objects larger than 50mm
2 Low Protected against objects larger than 12.5mm
3 Medium Protected against objects larger than 2.5mm
4 Good Protected against objects larger than 1mm
5 Dust Protected Limited dust ingress allowed
6 Dust Tight Completely protected from dust ingress
Second Digit – Protection Against Liquids (0–9K)
Digit Protection Level Description
0 None No protection
1 Dripping Water Vertically falling drops only
2 Tilted Dripping 15° from vertical
3 Spraying Water Up to 60° angle
4 Splashing Water From any direction
5 Water Jets Low-pressure water jets
6 Powerful Water Jets High-pressure jets
7 Immersion (1m) Temporarily submerged
8 Immersion (deeper) Long-term underwater use
9K High-pressure Steam High-temp, high-pressure washdowns
Why IP Rating Matters in Switchgear Cabinets
When it comes to electrical safety, IP rating is non-negotiable. Switchgear cabinets house critical components such as circuit breakers, transformers, and protective relays. Exposure to dust, water, or even accidental contact can lead to equipment failure, fire, or power outages.
Here's why selecting the right IP-rated cabinet is vital:
Ensures long-term reliability of electrical equipment.
Reduces maintenance frequency due to better environmental sealing.
Protects human operators from live electrical parts.
Complies with industry and safety regulations.
Common IP Ratings for Switchgear Cabinets
Here are the most commonly used IP ratings in switchgear applications:
IP54 – General Indoor Use
Offers limited dust protection and safeguards against splashing water. Ideal for residential or light industrial environments.
IP65 – Indoor/Outdoor Use
Fully sealed against dust from low-pressure water jets. Suitable for factories, data centers, or commercial buildings.
IP66 – Harsh Outdoor Environments
Completely dust-tight and resists powerful water jets, making it perfect for marine, mining, or remote field locations.
IP67 – Temporary Submersion
Offers the same dust-tight protection and can handle temporary immersion in water. Used in underground installations or flood-prone zones.
IP68/IP69K – Extreme Environments
For deep submersion or high-pressure steam cleaning, commonly used in food processing, chemical plants, or pharmaceutical industries.

How to Choose the Right IP Rating for Your Application
Choosing the correct IP rating depends on several factors:
1. Environment
Ask yourself: Will the cabinet be installed indoors or outdoors? Are there harsh weather conditions, dusty surroundings, or regular washdowns?
2. Application
Is the cabinet for low-voltage distribution, control panels, or motor starters? The more critical the equipment, the higher the IP rating should be.
3. Access Requirements
Some environments may require frequent cabinet access, which can compromise sealing. Choose a robust rating like IP66 in such cases.
4. Compliance Standards
Different countries and industries have specific safety standards. Ensure your cabinet meets local electrical codes and certifications.
Tips for Maintaining IP Ratings
Even the best switchgear cabinet can lose its IP rating if not handled properly. Here are a few tips to maintain protection:
Avoid frequent door opening in high-dust or wet environments.
Replace seals and gaskets when damaged or worn.
Use compatible cable glands and fittings that match the cabinet's IP rating.
Perform regular inspections to check for corrosion, rust, or leakage.
Train personnel on the importance of keeping the cabinet sealed.
Final Thoughts
Understanding IP ratings in switchgear cabinets isn't just for engineers — it's essential knowledge for anyone responsible for electrical infrastructure. A misjudged IP rating can lead to expensive downtime, safety hazards, or equipment failure. On the other hand, choosing the right enclosure can significantly extend the life of your equipment, boost performance, and ensure safe operations in any environment.
Whether you're designing a small control panel or overseeing a large-scale industrial project, take time to evaluate your environmental challenges, and don't hesitate to consult an experienced supplier who understands your needs.
FAQs
1. Can I upgrade an existing switchgear cabinet to a higher IP rating?
In most cases, no. IP ratings depend on the design, seals, and materials of the enclosure. Retrofitting typically doesn't guarantee compliance with a higher rating.
2. Are IP66 and NEMA 4X the same?
Not exactly. While they offer similar protection, NEMA 4X also includes resistance to corrosion, which IP66 does not necessarily guarantee. Always check with regional standards.
3. Do higher IP ratings mean better protection?
Not always. Higher isn't always necessary. For example, an IP68 cabinet is overkill for an air-conditioned indoor control room. Choose based on application, not just numbers.
4. What happens if the cabinet seal is broken?
The IP rating is no longer valid. Water, dust, or insects can enter, increasing the risk of short circuits, overheating, or fire hazards.
5. How do I verify a switchgear cabinet's IP rating?
Always check for certifications or lab-tested compliance documents from the manufacturer. Don't rely solely on product descriptions.